M3P Series

M3P Series

Commercial DC Fast Charging Station

  • Self-developed control module
  • Expandable design of split cabinet
  • Diversified scenario operation
  • Perfect choice for commercial use

 

PRODUCT INTRODUCTION

M3P series can be equipped with 1 or 2 charging guns, with an output power from 60kW to 240kW, which can charge most EVs with 80% of the mileage within 30 minutes.

M3P series is compatible with all types of Electric Vehicles currently on the market and complies with SAE J1772/CCS Type 1 charging plug.

PRODUCT HIGHLIGHTS

  • Integrated Smart HMI: 10-inch high-contrast LCD touchscreen
  • Safe and reliable, with multiple fault protection 
  • Ethernet RJ-45 interface networking is adopted, and 4G module is optional, compliant with the OCPP 1.6J protocol.
    Upgraded and adaptable to OCPP 2.0.1 protocol in 2024
  • APP, RFID charging control approval, with emergency stop function
  • Type 3R/IP54, dustproof, waterproof and anti-corrosion
  • Charging module separated from control system, stable and safe performance
  • Multiple module output in parallel, flexible configuration and easy maintenance
  • Constant power module and smart power allocation, high charging efficiency
  • All the control system can be remotely or locally upgraded

Components of DC Charging Station with & without Power Controller:

INJET INTEGRATED DC CHARGING STATION

  • DC watt-hour meter
  • Voltage detection transmitter
  • Insulation detector
  • Charging pile controller
  • 24V/12V AC/DC switching power supply(only for Chinese GB/T standard)
  • AC/DC power supply module
  • MCB, Relay, SPD
  • MCCB, AC Contactor
  • DC vacuum contactor
  • 600 pcs of terminal blocks+ 300 pcs wires

Maintenance of DC Charging Station with & without Power Controller:

1. Integrated controller maintenance less than 8 hours

  • Failure occurs: The background directly judges the fault----2~4 hours
  • Equipment needs to be replaced: Direct replacement of power controller----2~4 hours
  • Device back up and running

2. Traditional breakdown repair 2-10 days in total

  • Failure occurs: Maintenance personnel to the scene----1~2 days;
    Determine the fault point----- 1~2 days
  • Need accessories: Spare parts delivery---- 2~6 days; Repair and recovery ----1~2 days
  • Device back up and running

OUR SERVICES

  • OEM / ODM available.
  • 24/7 online service.
  • Technical support
  • Market analysis
  • Enabling policy

Programmable Power Controller(PPC)

Our Programmable Power Controller(PPC) is a highly integrated power module that contains multiple functional components. You can quickly build a DC charging station by assembling "Case+Charging Module+PPC+Connector". This technology revolutionized the way of manufacturing charging stations, and it significantly simplifies the assembly of charging station. By choosing our PPC, production efficiency is not the only thing you are improving.

FEATURES

  • Charging System: IEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-
    2,IEC 62196-3, IEC 6100
  • Communication Standard: ISO 15118, DIN 70121
  • Applicable power range: 60~200kW
  • Input work voltage range: 230 VAC +/- 10% (50 Hz or 60 Hz)
  • DC intput voltage range: 12 ~ 1000V
  • DC output voltage range: 12 ~ 1000V
  • DC intput maximum current: 250A
  • DC output maximum current: 250A
  • Number of outlet: 2
  • Communication to the backend: OCPP 1.6 JSON
  • Overvoltage category: Type Il
  • Standby power: 5W
  • Energy metering: Optional, MID metering for DC outlets
  • Communication Protocol: CPP 1.6J
  • Storage Temperature: -40°C to 75°C
  • perating Temperature: -20°C to 55°C, derating output in 55°C
  • Operating Humidity: Up to 95% non-condensing
  • Altitude: ≤2000m
  • Cooling Method: Natural cooling
  • Protection Ratings: IP00
  • Equipment Dimension(W×D×H):
    300mmx170mmx430mm
  • Equipment Weight: ≤ 12kg

Protection

  • Over Voltage Protection
  • Over Load Protection
  • Over-Temp Protection
  • Under Voltage Protection
  • Short Circuit Protection

  • Ground Protection

  • Surge Protection

 

Smart HMI

With our proud patents, various functional components are highly integrated to achieve 1/0 interaction and communication between the Programmable Power Controller (PPC) and the charging station. When building your charging stations, The only thing you need to do is to embed the smart HMI on the front or side facade of the station, then connect with the Programmable Power Controller (PPC). Technicians can easily control, program and operate the charging station when reducing cost of labor and time consumption.

 

FEATURES

  • Control power supply: 24VDC
  • SIM card type: NANO-SIM
  • Charging Control: App, RFID
  • Human-Machine Interface: 7" high-contrast touchscreen
  • Indicators: 4 LED indicators - Power / Fault / Charging A /
    Charging B
  • Network Interface: 3G/ 4G / Ethernet (Rj45)
  • Communication Protocol: OCPP 1.6J|
  • Storage Temperature: -40°C to 75°C
  • Operating Temperature: -20°C to 55°C, derating output in 55°C
  • Operating Humidity: Up to 95% non-condensing
  • Altitude: ≤ 2000m|
  • Cooling Method: Natural cooling
  • Protection Ratings: IP65
  • Equipment Dimension(W×D×H): 300mm×250mmx60mm
  • Equipment Weight: ≤ 2kg

 

Back to blog